40ft Container Cold Room systems provide an extended insulated storage space within a container enclosure, with refrigeration and controls selected for the application. TunelGroup plans the system around product quantity, loading pattern, required temperature and site conditions.
The longer format suits operations that need additional storage area within a single enclosure. Its layout must account for the full air-circulation path, access to stock and refrigeration service space. These details establish usable capacity and help avoid poorly cooled areas behind dense loads.
+12/+18°C
-5/+5°C
+5/-18°C
-18/-25°C
-30/-40°C
Each band represents a configuration to be specified for the project. The final operating range depends on the refrigeration system, insulation, ambient conditions and product load. Specialist low-temperature duties require a separate engineering assessment.
Chilled or frozen storage for packaged foods, ingredients and finished goods. A clear loading plan should identify stock locations, air gaps and the route used for receiving and dispatch.
An additional storage enclosure for harvest periods, seasonal demand or phased facility growth. Delivery access, lifting space and the installed footprint should be checked early in the project.
Crates and shelves can be arranged for product access and cooling airflow. Define the crop, entry temperature, cooling time and humidity requirements before selecting refrigeration and auxiliary equipment.
Establish the permitted temperature limits, monitoring locations, alarm strategy and qualification scope. Temperature mapping may be required to verify the proposed layout under the agreed operating conditions.
Use as a stationary store and use during transport have different requirements. Confirm transport power, equipment duty and approvals separately when goods must remain refrigerated in transit.
Assess package or pallet dimensions, shelf depth, aisle width and evaporator clearance before defining capacity. Nominal container length alone does not establish usable storage volume or the number of pallet positions.
Select air throw and distribution for the actual loaded room. Keep supply and return paths open, and review whether ducting, baffles or an alternative evaporator arrangement are needed for the project.
Organize the room so goods can be inspected and retrieved without repeated rearrangement. Door opening, threshold and floor loading must suit the proposed equipment; forklift access requires specific confirmation.
Allow clear space around the service end for condenser ventilation and maintenance. A planned inspection routine should include coils, drains, door seals, sensors and the recording or alarm system.
The pictured shelving and equipment arrangement illustrate one configuration. Storage layout, shelf supply, refrigeration equipment and finishes are confirmed in the project scope.
A project quotation should define the following items together. These details establish the supplied configuration and the work required at the installation site.
| Container format | 40ft class enclosure; final dimensions, handling weight and transport envelope confirmed on the drawing |
|---|---|
| Storage layout | Usable length, shelf or pallet positions, access aisles and equipment clearances set out before capacity is stated |
| Operating temperature | Project-specific configuration selected for the product and required holding conditions |
| Refrigeration duty | Product cooling, heat transmission, door infiltration, fans and other internal loads included in selection |
| Air distribution | Air throw, supply path, return route and any ducting assessed for the full loaded-room length |
| Insulation and floor | Thermal construction, vapor sealing, floor finish and allowable loads matched to the installation |
| Door and handling access | Clear opening, threshold and handling equipment checked against the loading plan |
| Electrical and site services | Power supply, protection, support surface, ventilation and condensate arrangements defined |
| Control and verification | Sensor locations, alarms, logging and any temperature-mapping or qualification requirements agreed |
Cooling duty matters: A longer container does not determine the required compressor size by itself. Product entry temperature, daily throughput, cooling time, ambient conditions and door activity remain essential calculation inputs.
Choose the format from the required usable capacity, loading arrangement and available installation space.
Provide the installation country and city, product type, target temperature, total stock, daily intake, entry temperature and required cooling time. Include package or pallet dimensions, the proposed loading plan, handling equipment, power supply, monitoring requirements and delivery-site access.
We manufacture industrial cooling systems panels, doors, cooling devices and ice machines under one roof!
Cold Storage Pioneer in Industrial Design
Manufacturing and Sales of Industrial Cold Storage Wall, Ceiling and Floor Panels
Manufacturing and Sales of Industrial Cold Storage Sliding, Hinged, Monorail and Flip-Flap Doors
Manufacturing and Sales of Split Type Hermetic, Semi-Hermetic and Double Stage Shock Devices for Industrial Cold Storage
Easy Installation Possibility with Modular Type Cold Rooms and Monoblock Cooling Devices
Manufacturing and Sales of Facade and Roof Panels for Exterior and Roof Covering of Industrial Warehouses
Manufacturing and Sales of Sectional, Office-Service and Fast Rolling Doors for Industrial Warehouses
Manufacturing and Sales of Industrial Cold Storage Ceiling Type and Standard Type Cooling Systems
Manufacturing and Sales of Ready-made System Container Cold Storages with Wall, Ceiling, Floor Insulation and Cooling Devices
We manufacture industrial cooling systems panels, doors, cooling devices and ice machines under one roof!
Contracting, Service and Engineering
Tunelgroup Industrial Cooling Systems; Manufactures and Sells Industrial Cooling Systems Panels, Doors and Cooling Devices. With its high engineering principles and perception of quality, it offers its customers efficiency-based, respected and sustainable services. Our company; From planning to design, from the project process to investment, from development to turnkey completion, it offers engineering services and professional solution partnerships in your investments with our own production steel construction systems.
By combining innovation, sustainability, and expertise, Tunel Group delivers cold storage for meat solutions that not only guarantee optimal preservation but also align with modern energy efficiency and sustainability standards.
With a commitment to quality, innovation, and sustainability, Tunel Group ensures that poultry producers and distributors can optimize cold storage for chicken conditions while reducing operational costs, providing reliable and sustainable solutions for the seafood industry.
With a commitment to quality, innovation, and sustainability, Tunel Group optimizes cold storage for fish conditions while reducing operational costs, providing reliable and sustainable solutions for the seafood industry.
By combining innovation, sustainability, and expertise, Tunel Group delivers advanced cold room solutions for fruits that meet the highest industry standards, ensuring your fruits remain fresh and market-ready.
By combining innovation, sustainability, and expertise, Tunel Group ensures your vegetables are stored in optimal cold room for vegetables conditions, extending shelf life and preserving quality.
By combining innovation, sustainability, and expertise, Tunel Group ensures your dairy products are stored in optimal cold storage for dairy conditions, extending shelf life and preserving quality.
With a commitment to quality, innovation, and sustainability, Tunel Group ensures that bakery producers can optimize cold storage for bakery conditions while reducing operational costs.
Our cutting-edge flower cold rooms create the perfect environment for flowers, minimizing wilting, discoloration, and decay while enhancing their natural beauty and longevity.
Our cold room systems are meticulously engineered to address the unique requirements of the pharmaceutical sector, guaranteeing optimal storage conditions throughout the entire product lifecycle.
Have questions or ready to take the next step? Contact us; we are here to help you on your cooling systems journey.
Mon-Fri: 09:00 - 18:00
Closed on Weekends
Dudullu Organize Sanayi Bölgesi, Nato Yolu Cd No:39, 34776
Y. Dudullu/Ümraniye/İstanbul
Kayapa, Kayapa OSB, 10. Sk. No:6, 16315
Ni̇lüfer/Bursa
Whether you are looking for guidance, planning a cold room or simply want more information, we have you covered.
Our Mega Structure Design and Manufacturing Efficiency is at the Top Level with Knowledge, Experience and Effective Engineering